{"id":9695,"date":"2021-06-09T09:22:30","date_gmt":"2021-06-09T02:22:30","guid":{"rendered":"https:\/\/arismadata.com\/solidworks\/blog\/?p=9695"},"modified":"2021-06-09T09:22:31","modified_gmt":"2021-06-09T02:22:31","slug":"menghilangkan-marking-pada-location-simbol-solidworks-electrical","status":"publish","type":"post","link":"https:\/\/arismadata.com\/solidworks\/blog\/2021\/06\/menghilangkan-marking-pada-location-simbol-solidworks-electrical\/","title":{"rendered":"Menghilangkan Marking \u201c+\u201d pada Location &#038; Simbol SOLIDWORKS Electrical"},"content":{"rendered":"\n<p>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Halo sobat <a href=\"https:\/\/arismadata.com\/solidworks\/blog\">SOLIDWORKS<\/a>, kali ini kita akan membahas mengenai SOLIDWORKS Electrical, ketika kita menggunakan template IEC pada project SOLIDWORKS Electrical biasanya kita akan ketemu dengan suatu marking yang bagi banyak orang Indonesia kurang terbiasa, apakah itu? Ya marking tersebut adalah \u201c+\u201d sering kali pengguna SOLIDWORKS Electrical menanyakan tentang cara menghilangkan marking tersebut, nah pada kesempatan kali ini kita akan mempelajari bagaimana caranya menghilangkan marking tersebut.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"692\" src=\"https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-1-1024x692.png\" alt=\"\" class=\"wp-image-9696\" srcset=\"https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-1-1024x692.png 1024w, https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-1-300x203.png 300w, https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-1-768x519.png 768w, https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-1.png 1267w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Nah sebelum kita masuk ke pembahasannya mari kita bahas dulu kenapa sih ada tanda \u201c+\u201d pada settingan marking tersebut, jadi jika merujuk pada standard IEC 61346 mengenai standarisasi marking, maka diwajibkan untuk kita memberikan tanda \u201c+\u201d didepan marking simbol yang apabila simbol tersebut yang merupakan komponen tidak berada pada posisi penempatan yang sama dengan lokasi drawing tempat simbol itu diletakkan, gimana \u2013 gimana ? kok jadi malah tambah pusing dengan penjelasannya, hehehe.<\/p>\n\n\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Jadi gini, kita sederhanakan saja konsepnya yah biar mudah dipahami, anggaplah kita punya 2 Schematics drawing, yang satu khusus untuk menempatkan simbol komponen yang nantinya akan dipasang di dalam Box Panel, dan yang satunya lagi khusus untuk simbol komponen yang akan dipasang di pintu dari Box Panel, sekarang kita sebut aja Drawing \u201cA\u201d untuk area Box Panel dan Drawing \u201cB\u201d untuk area Pintu Box Panel,<\/p>\n\n\n\n<p>Nah disisi lain kita akan memasukkan simbol lampu, kita tau bahwa lampu seharusnya dimasukkan pada Drawing \u201cB\u201d tetapi karena satu atau beberapa hal kita harus memasukkan simbol tersebut ke Drawing \u201cA\u201d nah untuk memberikan informasi maka sebuah informasi harus ditambahkan yaitu \u201c+\u201d dan nama lokasinya, dan biasanya lokasi itu dipersingkat dengan L1, L2, L3 dll, nah maka anggap saja markingnya menjadi +L1 dan marking ini akan semakin Panjang apabila kita meletakan simbol yang tidak sesuai dengan tempatnya (lihat gambar 1 pada simbol +L1+L11-Q5), dengan ide seperti itu maka IEC mengeluarkan standarisasi sistem marking yang sebenarnya sangat baik,<\/p>\n\n\n\n<p>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Tetapi bagi Anda yang mau menggunakan standard IEC dalam Project di <a href=\"https:\/\/arismadata.com\/solidworks\/products-electrical.php\" title=\"solidworks electrical\">SOLIDWORKS Electrical<\/a> dan tidak mau menggunakan standarisasi marking seperti dijabarkan diatas, maka Anda bisa lakukan hal ini pada SOLIDWORKS Electrical Anda untuk menghilangkannya:<\/p>\n\n\n\n<ol class=\"wp-block-list\" type=\"1\"><li>Pada Ribbon Menu, masuk ke tab \u201cProject\u201d<\/li><li>Klik menu \u201cConfigurations\u201d<\/li><li>Pada menu tersebut masuk ke tab \u201cMark\u201d<\/li><li>Kemudian lihat dibagian bawah ada area \u201cMark\u201d fokus ke bagian \u201cMark mode\u201d<\/li><li>Pindahkan pilihan ke \u201cCustomized mark\u201d dari yang sebelumnya \u201cIEC 61346\u201d<\/li><li>Klik \u201cApply\u201d dibagian bawah<\/li><li>Lalu Klik \u201cOK\u201d untuk mengakhiri menu<\/li><\/ol>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"730\" src=\"https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-2-1024x730.png\" alt=\"\" class=\"wp-image-9697\" srcset=\"https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-2-1024x730.png 1024w, https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-2-300x214.png 300w, https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-2-768x548.png 768w, https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-2.png 1182w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Nah maka sekarang settingan Marking Anda sudah sesuai yang diharapkan deh,<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"692\" src=\"https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-3-1024x692.png\" alt=\"\" class=\"wp-image-9698\" srcset=\"https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-3-1024x692.png 1024w, https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-3-300x203.png 300w, https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-3-768x519.png 768w, https:\/\/arismadata.com\/solidworks\/blog\/wp-content\/uploads\/2021\/06\/sw-electrical-3.png 1267w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>Selamat mencoba ya sobat SOLIDWORKS Electrical semuanya,<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Halo sobat SOLIDWORKS, kali ini kita akan membahas mengenai SOLIDWORKS Electrical, ketika kita menggunakan template IEC pada project SOLIDWORKS Electrical biasanya kita akan ketemu dengan suatu marking yang bagi banyak orang Indonesia kurang terbiasa, apakah itu? Ya marking tersebut adalah \u201c+\u201d sering kali pengguna SOLIDWORKS Electrical menanyakan tentang cara menghilangkan marking tersebut, nah pada [&hellip;]<\/p>\n","protected":false},"author":14,"featured_media":9696,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1118,3,578,1207,1208,702,816,1070,323],"tags":[1445,1446,1447,506,559],"class_list":["post-9695","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-3dexperience","category-artikel-solidworks","category-design-3d","category-jasa-desain-3d","category-jasa-gambar","category-solidworks-2018","category-solidworks-2019","category-solidworks-2020","category-solidworks-electrical","tag-iec","tag-location","tag-marking","tag-simbol","tag-solidworks-electrical"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/posts\/9695","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/comments?post=9695"}],"version-history":[{"count":0,"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/posts\/9695\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/media\/9696"}],"wp:attachment":[{"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/media?parent=9695"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/categories?post=9695"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/arismadata.com\/solidworks\/blog\/wp-json\/wp\/v2\/tags?post=9695"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}